HP Remote Insight Lights-Out Edition II Board User Manual
Page 115

Scripting, command line, and utility options 115
If you click Next, or Back, or exit the application during discovery, operations on the current network
address are completed, but those on subsequent network addresses are canceled.
To start the process of discovering your management processors:
1.
Click Start and select Programs>Hewlett-Packard, Lights-Out Migration Utility.
2.
Click Next to move past the Welcome page.
3.
Enter the address or address range you want to search for management processors in the Addresses
field.
4.
Enter your login name and password. Click Find or click Import to use a file. When the search is
complete, the Find button changes to Verify.
When using a file to enter a list of management processors, the file must be a simple text file with
one management processor listed per line using semicolon delimited fields. The fields are delimited
in the following order:
•
Network Address
•
Management Processor Type
•
Firmware Version
•
DNS Name
•
User Name
•
Password
•
Directory Configuration
For example, one line could have:
16.100.225.20;RILOEII;1.20;RILOE2DB;user;password;Default Schema
If for security reasons, you cannot store the user name and password in the file, leave these fields
empty and delimitated with semicolons.