HP 3Gb SAS Switch for HP BladeSystem c-Class User Manual
Page 76
2.
Assign the zone group to the server device bay.
This example shows how to assign ozone group zone5 to server device bay 5.
=> sw local startupdate
Success
=> bb 5 add zg=zone5
Success
=> sw local saveupdate
Success
3.
[Optional] Verify that the zone group was assigned as intended.
For example, use one of the following commands:
=> bb all show detail
=> sw local zg all show detail
The display of this example is abbreviated, retaining key details. Zone group zone5 is now
assigned to server device bay 5.
=> sw local zg all show detail
Blade Enclosure at BottomC7000
Switch: Local
Zone Group: zone1
Zoned Storage Enclosure Bay: 71:1:1
Zoned Storage Enclosure Bay: 71:1:2
Zoned Storage Enclosure Bay: 71:1:3
Zoned Storage Enclosure Bay: 71:1:4
Zoned Storage Enclosure Bay: 71:1:5
Zoned Storage Enclosure Bay: 71:1:6
Zoned Storage Enclosure Bay: 71:1:7
Assigned Blade Bay: 1
Zone Group: zone2
Zoned Storage Enclosure Bay: 71:1:8
Zoned Storage Enclosure Bay: 71:1:9
Zoned Storage Enclosure Bay: 71:1:10
Zoned Storage Enclosure Bay: 71:1:11
Zoned Storage Enclosure Bay: 71:1:12
Zoned Storage Enclosure Bay: 71:1:13
Zoned Storage Enclosure Bay: 71:1:14
Assigned Blade Bay: 2
-
-
-
Zone Group: zone5
Zoned Storage Enclosure Bay: 71:1:29
Zoned Storage Enclosure Bay: 71:1:30
Zoned Storage Enclosure Bay: 71:1:31
Zoned Storage Enclosure Bay: 71:1:32
Zoned Storage Enclosure Bay: 71:1:33
Zoned Storage Enclosure Bay: 71:1:34
Zoned Storage Enclosure Bay: 71:1:35
Assigned Blade Bay: 5
76
Performing common tasks