beautypg.com

Zoning requirements and device mappings – HP 3Gb SAS Switch for HP BladeSystem c-Class User Manual

Page 7

background image

Zoning requirements and device mappings

IMPORTANT:

Depending on the BladeSystem c-Class enclosure model, server type, mezzanine slot used,

BladeSystem server device bay, and BladeSystem interconnect bay, the zone groups that assigned to a
server must be associated with storage enclosures connected to switch ports 1–4 or 5–8. Failure to follow
these guidelines will result in an unsupported configuration.

The following tables show the interdependencies of components in an HP BladeSystem c-Class solution that
includes an HP StorageWorks 3Gb SAS BL Switch connected to external SAS storage enclosures.

For the c3000 BladeSystem enclosure, use the following table to determine which external storage enclosures
to use when zoning the external storage to the server blades.

For example, as shown in the table, if a full-height server blade is installed in device bay 1-8 of a c3000
enclosure, and the P700m SAS Controller is installed in server mezzanine slot 2; the 3Gb SAS BL Switch
must be installed in BladeSystem interconnect bay 3 or 4 and it should be assigned a zone group that is in
an external storage enclosure attached to 3Gb SAS BL Switch ports 1, 2, 3, or 4.

Zone groups must be in
storage enclosures

nl

connected to these 3Gb
SAS BL Switch ports

BladeSystem

nl

c-Class

nl

interconnect bay

BladeSystem

nl

c-Class

nl

device bay

Mezzanine slot

Server type

BladeSystem

nl

c-Class

nl

enclosure

nl

model

1 – 4

3/4

Any

2

Half height

c3000

1 – 4

3/4

Any

2

Full height

5 – 8

3/4

Any

3

1 – 4

3/4

1A – 8A

“A-side”

Half height

nl

Double dense

nl

(BL2x220c)

5 – 8

3/4

1B – 8B

“B-side”

1 – 4

3/4

Any

2

Full height

nl

Double wide

nl

(BL680c G7)

5 – 8

3/4

Any

3

5 – 8

3/4

Any

4

1 – 4

3/4

Any

7

Zoning requirements and device mappings

7