NOTE:

If the Reset Storage Enclosure task is not displayed, consider the following:

Storage enclosure model—Only supported storage enclosures can be reset.

Switch status—If the status is a value other than Active or Not Redundant, resetting the storage
enclosures is not allowed. Also, if the switch is in the process of a firmware update, that
process must complete and the switch return to an operational state before any storage
enclosures can be reset.

Server blade status—All server blades in the c-Class enclosure must be powered off to perform
this task.

To perform this task, expand the display for the active switch in the navigation tree, and then click
Reset Storage Enclosure.

NOTE:

Before resetting a storage enclosure, make sure that all I/O to the enclosure is halted. Power
down all hosts and restart them after the enclosure completes the reset.

This task is required after updating storage enclosure firmware.

After the reset is complete, click the refresh icon to ensure that you are viewing the most recent
status information. Confirm that the status of the storage enclosure is acceptable. Correct any
issues as needed.

Reset Storage Enclosure task