Table 6 Whether hosts can access P-VOLs and S-VOLs

P-VOL

S-VOL

Pair status

Read

Write

Read

Write

SMPL

OK

OK

COPY

OK

OK

No

No

PAIR/PFUL

OK

OK

No

No

PSUS/PFUS

OK

OK

OK

OK

SMPL(PD)

OK

OK

No

No

COPY(RS)

OK

OK

No

No

COPY(RS-R)

OK

OK

No

No

PSUE

OK

1

OK

1

No

No

1

If the pair status changes to PSUE because a failure occurred during the restoration, the host cannot access that pair.

CAUTION:

If the host computer uses application software to monitor the Snapshot XP pairs' volumes, problems, such

as abnormal end, might occur. For example, since the S-VOL whose status is not PSUS (or PFUS) rejects

access from the host, a problem might occur on the monitoring application software whose access is

rejected. In addition, if the host computer connects to more than one port, a problem might also occur

on ports that are not connected to the S-VOL that rejected the host access. You must terminate the

application software monitoring the volumes to solve these problems.

Use RAID Manager XP commands to operate Snapshot XP pairs. However, whether the operations

complete normally or not depends on the pair status.

Table 7

shows the pair status and results of the

RAID Manager commands.

Table 7 Pair status and results of RAID Manager XP commands

RAID Manager XP command

1

Pair

status

paircreate paircreate

-split

pairsplit

pairresync pairresync

-restore

pair-

split -S

pair-

split -E

SMPL

OK

No

No

No

No

NOP

No

COPY

NOP

No

No

NOP

NOP

No

No

PAIR/PFUL NOP

OK

OK

NOP

NOP

OK

No

PSUS/

PFUS

No

NOP

NOP

OK

OK

OK

No

SMPL(PD)

No

No

No

No

No

NOP

No

COPY(RS)

NOP

No

No

NOP

NOP

No

No

COPY(RS-R) NOP

No

No

NOP

NOP

No

No

PSUE

NO

No

No

OK

2

No

OK

NOP

1

OK: Command executes the process and ends normally.

NOP: Command does not execute the process, but ends normally.
No: Command ends abnormally (that is, command is rejected).

2

If you issue the pairresync command for a pair whose status has changed to PSUE because of a shortage of shared memory

for the V-VOL management area, the command is rejected and ends abnormally.