Other Error Messages
Message
Condition
Solution
Following SCSI disk
not found and NO
empty slot available
for mapping it
The physical drive
roaming feature failed to
find the physical drive
with the listed SCSI ID,
and no slot is available in
which to map the physical
drive.
Reconfigure the array.
Battery life low
The battery backing the
cache memory is
approaching its predicted
end of life.
Return the battery to HP for
replacement.
Warning: Battery
voltage low
The voltage of the battery
backing the cache is low.
Fast charge the battery.
Battery temperature
out of range
The temperature of the
battery backing the cache
is abnormal.
If the battery is too cold, allow it to
warm up first. If the battery is too hot,
check for system overheating or fan
failure. The battery will not fast charge
if the temperature is out of range.
Other Error Messages
Questions and Answers
What is the maximum number of HP NetRAID
Adapters per NetServer?
Currently, all the utilities and drivers support
up to six HP NetRAID adapters per system.
Why does a failed logical array still get a drive
assignment?
To maintain the DOS Path statement
integrity.