H. exiting hp netraid config – HP NetRAID 1 Controller User Manual
Page 46

42
Manual Rebuild with Batch Mode
1. Choose Rebuild from the HP NetRAID Config Management Menu. A device selection
window is displayed showing the devices connected to the current adapter. The failed drives
have FAIL indicators.
2. Press the arrow keys to highlight all drives to be rebuilt. Press the spacebar to select the
highlighted physical drive for rebuild.
3. After selecting the physical drives, press F10 and type Yes at the confirmation prompt. The
indicators for the selected drives changes to REBLD. Rebuilding can take some time,
depending on the number of drives you have selected and their capacities.
4. When rebuild is complete, press any key to continue. Press Esc to return to the Management
Menu.
H. Exiting HP NetRAID Config
To exit HP NetRAID Config, press Esc at the Management Menu and choose “Yes” at the prompt.
A message appears if there are uninitialized logical drives in the system.