beautypg.com

Bios error messages – HP NetRAID 1 Controller User Manual

Page 64

background image

60

BIOS Error Messages

Physical Drive Roaming

Message

Condition

Solution

Error: Following
SCSI disk not found
and no empty slot
available for mapping
it.

No slot to map the disk;
controller cannot
complete roaming due to
missing disk.

Reconfigure the array because the
adapter cannot resolve the physical
drives into the current configuration.

Following SCSI IDs
have the same data
Channel-
x:a,b,c

Two or more drives (a, b,
c, etc.) on channel x have
the same information,
controller cannot resolve
which drive to use.

Remove one or more drives to leave
only one with the duplicated data to
complete roaming.

Unresolved
Configuration
Mismatch

Unresolved configuration
mismatch between disk(s)
and NVRAM on the
adapter.

Fix in HP NetRAID Express Tools by
examining both configurations with
View/Add Configuration and selecting
the configuration to use.

Drive Roaming Done

SCSI drives not found at
correct positions; drive
roaming completed by
firmware

No correction required.

Physical Drive Roaming Error Messages