Bios error messages – HP NetRAID 1 Controller User Manual
Page 64

60
BIOS Error Messages
Physical Drive Roaming
Message
Condition
Solution
Error: Following
SCSI disk not found
and no empty slot
available for mapping
it.
No slot to map the disk;
controller cannot
complete roaming due to
missing disk.
Reconfigure the array because the
adapter cannot resolve the physical
drives into the current configuration.
Following SCSI IDs
have the same data
x:a,b,c
Two or more drives (a, b,
c, etc.) on channel x have
the same information,
controller cannot resolve
which drive to use.
Remove one or more drives to leave
only one with the duplicated data to
complete roaming.
Unresolved
Configuration
Mismatch
Unresolved configuration
mismatch between disk(s)
and NVRAM on the
adapter.
Fix in HP NetRAID Express Tools by
examining both configurations with
View/Add Configuration and selecting
the configuration to use.
Drive Roaming Done
SCSI drives not found at
correct positions; drive
roaming completed by
firmware
No correction required.
Physical Drive Roaming Error Messages