beautypg.com

Privilege elevation, Reporting, Property pages – HP Systems Insight Manager User Manual

Page 195

background image

3.

Right-click the Systems Insight Manager service in Windows Services API, and click restart
from the dropdown menu.

Privilege elevation

When “DISPLAY_LAST_LOGIN” = 1 in HP-UX, even non-interactive logins, such as used by
sudo, emit the Last login string. This extraneous data in stderr/stdout can affect tools.
This value can be changed using HP SMH in the Auditing and Security Attributes Configuration
section of the HP SMH home page. This can be done for the user whose rights have been elevated
(typically “root”) or set as the system-wide default for all users.
To make these changes, run the following commands:
For an individual user:

/usr/sbin/userdbset –u DISPLAY_LAST_LOGIN=0

For the system-wide default:

/usr/sbin/ch_rc –a –p DISPLAY_LAST_LOGIN=”0” /etc/default/security

Property pages

I am receiving an error when clicking the Fans link on the Property pages Configuration tab.
Solution: Upgrade to HP ProLiant WBEM Providers 2.3.
-------------------------------------------------------------
The Property pages for the VMWare ESX (Non-Embedded) operating system are not available
due to limitations in the WBEM agents.

Reporting

The reporting engine main page contains the Reports by Product table that displays the products
registered with HP SIM along with the available reports.

Procedure 54 CMS installed on Windows

1.

Open the reports.xml file located in the following path:

/config/preload/6x or
7x/addfiles/reports.xml

/config/preload-plugins/6x or
7x//addfiles/reports.xml

2.

Enter a space at the end of the file to change the timestamp and re-save the file.

3.

Execute the mxconfigrefresh command at the command prompt.

Procedure 55 CMS installed on HP-UX or Linux

1.

Open the reports.xml file located in the following path:

/etc/opt/mx/config/preload/6x or 7x/addfiles/reports.xml

/etc/opt/mx/config/preload-plugins/6x or 7x//
addfiles/reports.xml

2.

Enter a space at the end of the file to change the timestamp and re-save the file.

3.

Execute the mxconfigrefresh command at the command prompt.

After completing the procedure, the links to reports appear in the user interface.

Procedure 56 Enhanced Reports

When the Windows Log on policy is set or HP SIM is upgraded to any newer version, the Enhanced
Reports (Insight Control Power Reports and Customized Reports) stop working and the database
user account gets locked out.
To resolve this problem:
1.

Check whether the Windows Security Policy is enabled to lock the user account after few
unsuccessful log on attempts.

Privilege elevation 195