2007

2007: Error trying to get privilege info to adjust system time; error number
was errnum

TimeSync could not obtain Windows privilege information in preparation for updating the
local system time.

errnum

is the Windows system error that occurred.

Cause. TimeSync encountered a problem trying to get privilege data while preparing to
update the local system clock. In most cases, this is a security-related issue.

Effect. TimeSync does not adjust the local system time.

Recovery. Verify that TimeSync is running with Administrator permissions and that
security policy on the system is not set up to prevent time adjustments by the TimeSync
process.

2008

2008: Error trying to set privileges in order to adjust system time; error
number was errnum

TimeSync could not set Windows privileges in preparation for updating the local system
time.

errnum

is the Windows system error that occurred.

Cause. TimeSync encountered a problem trying to set its privileges while preparing to
update the local system clock. In most cases, this is a security-related issue.

Effect. TimeSync does not adjust the local system time.

Recovery. Verify that TimeSync is running with Administrator permissions and that
security policy on the system is not set up to prevent time adjustments by the TimeSync
process.