1005: TimeSync shutting down

TimeSync is shutting down normally.

Cause. The operator or system initiated a shutdown of the TimeSync process.

Effect. TimeSync shuts down.

Recovery. Not applicable.

1006

1006: Error initializing application socket: description

TimeSync could not initialize an application socket.

description

is the description of the error condition encountered.

Cause. TimeSync could not obtain a socket from the communication infrastructure.

Effect. TimeSync shuts down.

Recovery. Check the system log and/or TimeSync log for additional messages detailing
the specific cause of the error. Check to be sure that all network infrastructure is up and
running (network device drivers, TCP/IP processes/daemons, etc.), and ensure that
TimeSync is not configured to use a LocalPort that is currently being used by a different
application.

1007

1007: Select error on application socket, error number errnum

TimeSync could not perform a select operation on an application socket (OSS, Linux, and
Windows only).

errnum

is the specific error number returned by the sockets interface layer.

Cause. An internal error in the sockets infrastructure.

Effect. TimeSync delays and then retries the operation.

Recovery. Check the system log and/or TimeSync log for additional messages. Check to