HP NonStop G-Series User Manual
Page 45
![background image](/manuals/397971/45/background.png)
HP NonStop Time Synchronization User’s Guide
Page 45 of 81
0x02000000
Data sent via UDP
0x04000000
Data received via TCP
0x08000000
Data sent via TCP
0x10000000
Data received via NTP
0x20000000
Data sent via NTP
Value Range: 0x00000000 – 0x0FFFFFFF
Default Value: 0x00000003 (critical and noncritical errors)
Example: Mask = 0x0F80003F
RecordLimit
Defines the maximum number of trace records to capture, where 0 = no limit. Once this
limit is reached, no further trace records are captured unless Wrap is True.
Value Range: 0 through 2147483647, where 0 = no limit
Default Value: 1000
Example: RecordLimit = 2500
Wrap True | False
If True, the trace wraps when the record limit is reached. Whenever a new trace record is
captured, the oldest trace record is deleted.
Value Range: True or False
Default Value: False
Example: Wrap = True