HP NonStop G-Series User Manual
Page 74
HP NonStop Time Synchronization User’s Guide
Page 74 of 81
Recovery. Verify that TimeSync is running with Administrator permissions and that
security policy on the system is not set up to prevent time adjustments by the TimeSync
process.
2005
2005: Error trying to get system time adjustment parameters; error number
was errnum
TimeSync could not obtain Windows system clock adjustment information.
errnum
is the Windows system error that occurred.
Cause. TimeSync encountered a problem trying to get details on current Windows clock
adjustment settings. In most cases, this is a security-related issue.
Effect. TimeSync does not adjust the local system time.
Recovery. Verify that TimeSync is running with Administrator permissions and that
security policy on the system is not set up to prevent time adjustments by the TimeSync
process.
2006
2006: Error trying to get token info to adjust system time; error number
was errnum
TimeSync could not obtain Windows token information in preparation for updating the
local system time.
errnum
is the Windows system error that occurred.
Cause. TimeSync encountered a problem trying to get its process token data while
preparing to update the local system clock. In most cases, this is a security-related issue.
Effect. TimeSync does not adjust the local system time.
Recovery. Verify that TimeSync is running with Administrator permissions and that
security policy on the system is not set up to prevent time adjustments by the TimeSync
process.