Ethernet switch 6600–24g, Environmental, Ethernet switch 6600–24g environmental – HP 9000 Virtual Library System User Manual
Page 231

Ethernet Switch 6600–24G
Specification
Item
21.5 x 17.4 x 1.7 in. (54.61 x 44.2 x 4.32 cm) 1U height
Dimensions
17.2 lb (7.8 kg) fully loaded
Weight
20 auto-sensing 10/100/1000 ports (IEEE 802.3 Type 10Base-T,
IEEE 802.3u Type 100Base-TX, IEEE 802.3ab Type 1000Base-T); 1
Ports
RJ–45 serial console port; 4 dual-personality ports, each of which can
be used as either an RJ-45 10/100/1000 port or an open mini-GBIC
slot (for use with mini-GBIC transceivers)
Freescale PowerPC 8540 @ 666 MHz, 4 MB flash, 256 MB compact
flash, 256 MB DDR SDRAM; packet buffer size: 36 MB QDR SDRAM
total (18 MB for 1 GbE/10-GbE ports)
Memory and Processor
< 3.4 μs (FIFO 64-byte packets)
1000 Mb Latency
< 2.4 μs (FIFO 64-byte packets)
10 Gbps Latency
up to 75.7 million pps (64-byte packets)
Throughput
101.8 Gbps
Routing/Switching capacity
105.6 Gbps
Switch fabric speed
10000 entries
Routing table size
64000 entries
MAC address table size
697 BTU/hr (735.33 kJ/hr)
Maximum heat dissipation
100-120/200-240 VAC
Voltage
167.6 W
Idle power
204.3 W
Maximum power rating
50/60 Hz
Frequency
Environmental
Shipping
Non-operating
Operating
-40°C to 66°C (-40°F
to 150°F)
-40°C to 66°C (-40°F
to 150°F)
10°C to 35°C (50°F
to 95°F)
Temperature
1
5% to 95%
10% to 95%
40% to 60%
Relative humidity (noncondensing)
2
-1000 ft to 40,000 ft
-1000 ft to 10,000 ft
-1000 ft to 10,000 ft
Altitude
5-1000-5 Hz, 2.0 g,
sinusoidal, 1
Octave/min., 3-axis
5-1000-5 Hz, 1.0 g,
sinusoidal, 1
Octave/min., 3-axis
5-1000-5 Hz, 0.25 g,
sinusoidal, 1
Octave/min., 3-axis
Vibration
30 g, every 11ms,
1/2 sine pulse, 3 axis
25 g, every 11ms,
1/2 sine pulse, 3 axis
5 g, every 11ms, 1/2
sine pulse, 3 axis
Shock
1
All temperature ratings shown are for sea level. An altitude derating of 1°C per 300 m (1.8°F per 1,000 ft) to 3048 m
(10,000 ft) is applicable. No direct sunlight allowed.
2
Storage maximum humidity of 95% is based on a maximum temperature of 45°C (113°F). Altitude maximum for storage
corresponds to a pressure minimum of 70 KPa.
Ethernet Switch 6600–24G
231