Fdd (flexible disk drive or floppy) tests – HP Netserver L Server series User Manual

Page 50

background image

Chapter 5

Error Message Reference

46

Code

Description

Recommended Action

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

01A2h

TagRAM Control
Register Test Failed.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

01A4h

L2 cache Commands
Test Failed.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Check system fans. If overheating occurs, chip may shut down.

6. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

7. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

01A3h

L2 cache Commands
Test Failed.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

FDD (Flexible Disk Drive or Floppy) Tests

Flexible Disk Drives are tested for rotational speed, elevator, and seek channel.

Code

Description

Recommended Action

0301h

Undefined or
invalid command.

1. Try a different diskette.

2. Check the cable between the floppy drive and the system board.

3. Change the floppy drive.