beautypg.com

HP Netserver L Server series User Manual

Page 38

background image

Chapter 5

Error Message Reference

34

Code

Description

Recommended Action

8. If the system ran with temperature high, let it cool for 30 minutes, then restart.

9. If system repeatedly shows this error, replace PCI Card and system board.

008Ah

BCI bus transfer
using PCI bus
master cycles failed.

1. Remove all unnecessary PCI cards and try the test again. If it still fails, make
sure all PCI connectors are seated.

2. Make sure the system board is seated.

3. Check the seating of the voltage regulator module (VRM) if present.

4. Be sure the processor board (if any) is seated.

5. Make sure the CPU chip is seated. (Take ESD precautions.)

6. Make sure the memory elements (DIMMs) are properly seated.

7. Check system fans. If overheating occurs, chip may shut down.

8. If the system ran with temperature high, let it cool for 30 minutes, then restart.

9. If system repeatedly shows this error, replace PCI Card and system board.

0090h

PnP function 00
failed.

1. Clear CMOS per instructions on technical reference label or card.

2. Run Configuration Assistant from the Navigator CD-ROM.

3. Check BIOS version and update the BIOS.

4. Change the system boards.

0091h

PnP Function 01
failed.

1. Clear CMOS per instructions on technical reference label or card.

2. Run Configuration Assistant from the Navigator CD-ROM.

3. Check BIOS version and update the BIOS.

4. Change the system boards.

0094h

Number of system
device nodes is not
same as reported.

1. Clear CMOS per instructions on technical reference label or card.

2. Run Configuration Assistant from the Navigator CD-ROM.

3. Check BIOS version and update the BIOS.

4. Change the system boards..

0095h

One or more nodes
have larger than
reported size.

1. Clear CMOS per instructions on technical reference label or card.

2. Run Configuration Assistant from the Navigator CD-ROM.

3. Check BIOS version and update the BIOS.

4. Change the system boards.

0096h

ISA bus detected
twice.

Replace System BIOS.

0097h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

0098h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

0099h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

009Ah

PnP function 40
failed.

Replace System BIOS.

009Bh

Invalid number of
PnP cards.

Update System BIOS.

009Ch

One or more

Check all PnP devices.