Chapter 5

Error Message Reference

42

Code

Description

Recommended Action

location
XXXXXXXXh.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0130h

The pattern written
at XXXXXXXXh
was qqqqh. The
pattern read back
from that address
was pppph.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0131h

Parity failure at
XXXXXXXXh
during pattern test.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0132h

Faulty Memory Chip
is on DIMM socket
YYYY.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0135h

ECC Correctable
Error in DIMM
socket YYYY.

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.

3. Visually inspect DIMM units to ensure they are properly seated.

4. Check the positions of DIMMs to see that positioning matches that on the
technical reference label or card.

5. Examine the support ticket and check for failures.

6. Bring the system down to its minimum memory configuration and rerun the
test.

7. Build up the system by halves until the failure is located.

0136h

ECC Uncorrectable
Error in

1. Visually inspect the memory board to ensure proper seating.

2. Check to see all DIMMs are the correct HP part number.