Chapter 5

Error Message Reference

31

Code

Description

Recommended Action

Clock CMOS RAM
are different from
that of written.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

0070h

The battery backup
unit that powers
CMOS RAM has no
power.

Replace battery, if one is present. (Check technical reference label or card.)

0071h

Bad CMOS RAM
checksum detected.

1. Run the BIOS Setup program and reconfigure all settings.

2. If necessary, update the BIOS.

3. Clear the CMOS and rerun configuration. See directions on the technical
reference label or card.

4. Make sure the system board is seated.

5. Check the seating of the voltage regulator module (VRM) if present.

6. Be sure the processor board (if any) is seated.

7. Make sure the CPU chip is seated. (Take ESD precautions.)

8. Make sure the memory elements (DIMMs) are properly seated.

9. Check system fans. If overheating occurs, chip may shut down.

10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

11. If system repeatedly shows this error, replace the element with the CMOS.

0072h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

0073h

CMOS RAM
memory size

Run BIOS Setup-- If problem persists replace battery, if present. Then replace
the system board.

0074h

CMOS RAM time is
invalid.

Run BIOS Setup if problem persists replace battery, if present. Then replace the
system board.

0075h

Time-base frequency
divider set at
incorrect value.

Reset the system and set BIOS Setup parameter. If the problem persists--replace
CMOS RAM and the battery.

0076h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

0077h

Periodic time update
cycle not occurring.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.