Error Message Reference

39

Code

Description

Recommended Action

5. Check the seating of the voltage regulator module (VRM) if present.

6. Be sure the processor board (if any) is seated.

7. Make sure the CPU chip is seated. (Take ESD precautions.)

8. Make sure the memory elements (DIMMs) are properly seated.

9. Check system fans. If overheating occurs, chip may shut down.

10. If the system ran with temperature high, let it cool for 30 minutes, then
restart.

11. If system repeatedly shows this error, replace the element with the CMOS.

00C0h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

00C1h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

00C2h

DiagTools Error

Download a new version of DiagTools from the HP web site and run it. If you get
the same error, call the HP Customer Care Center.

00C3h

MMX Regs.
Read/Write failed.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

00C4h

Wraparound
Arithmetic test
failed

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

00C5h

Saturation
Arithmetic test
failed.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.

3. Be sure the processor board (if any) is seated.

4. Make sure the CPU chip is seated.

5. Make sure the memory elements (DIMMs) are properly seated.

6. Check system fans. If overheating occurs, chip may shut down.

7. If the system ran with temperature high, let it cool for 30 minutes, then restart.

8. If system repeatedly shows this error, replace the CPU chip or board, as
appropriate.

00C6h

Pack with signed
saturation failed.

1. Take ESD precautions and make sure the system board is seated.

2. Check the seating of the voltage regulator module (VRM) if present.