Systems insight display led combinations – HP ProLiant DL360 G7 Server User Manual
Page 14

Component identification 14
Item
Description
Status
For possible failure causes, see "Systems
Insight Display LED combinations (on
page
)."
Systems Insight Display LED combinations
When the health LED on the front panel illuminates either amber or red, the server is experiencing a health
event. Combinations of illuminated Systems Insight Display LEDs, the system power LED, and the health LED
indicate system status.
Systems Insight Display
LED and color
Health LED
System power
LED
Status
Processor (amber)
Red
Amber
One or more of the following conditions may
exist:
•
Processor in socket X has failed.
•
Processor X is not installed in the socket.
•
Processor X is unsupported.
•
ROM detects a failed processor during
POST
Processor (amber)
Amber
Green
Processor in socket X is in a pre-failure
condition.
DIMM (amber)
Red
Green
One or more DIMMs have failed.
DIMM (amber)
Amber
Green
DIMM in slot X is in a pre-failure condition.
Overtemperature (amber) Amber
Green
The Health Driver has detected a cautionary
temperature level.
Overtemperature (amber) Red
Amber
The server has detected a hardware critical
temperature level.
Interlock (amber)
Red
Green
The PCI riser board assembly is not seated
properly.
Fan (amber)
Amber
Green
One fan has failed or has been removed.
Fan (amber)
Red
Green
Two or more fans have failed or been
removed.
Power supply (amber)
Red
Amber
•
Only one power supply is installed and
that power supply is in standby.
•
Power supply fault
•
System board fault
Power supply (amber)
Amber
Green
•
Redundant power supply is installed and
only one power supply is functional.
•
AC power cord is not plugged into
redundant power supply.
•
Redundant power supply fault
•
Power supply mismatch at POST or
power supply mismatch through hot-plug
addition.
Power cap (off)
—
Amber
Standby
Power cap (green)
—
Flashing green
Waiting for power
Power cap (flashing
amber)
—
Amber
Power cap has been exceeded.