Hp 1200 w cs he power supply (90%) specifications – HP ProLiant DL360 G7 Server User Manual
Page 112

Specifications 112
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.9 A at 100 VAC
4.3 A at 200 VAC
Rated input power
857 W at 100V AC input
824 W at 200V AC input
BTUs per hour
2925 at 100V AC input
2812 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
HP 750 W CS Platinum Power Supply (94%) specifications
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
8.6 A at 100 VAC
4.2 A at 200 VAC
Maximum rated input power
841 W at 100V AC input
809 W at 200V AC input
BTUs per hour
2868 at 100V AC input
2761 at 200V AC input
Power supply output
Rated steady-state power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
Maximum peak power
750 W at 100V to 120V AC input
750 W at 200V to 240V AC input
HP 1200 W CS HE Power Supply (90%) specifications
Specification
Value
Input requirements
Rated input voltage
100 to 120 VAC, 200 to
240 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
9.7 A at 100 VAC
7.0 A at 200 VAC
Maximum rated input power
930 W at 100V AC input
1348 W at 200V AC input
BTUs per hour
3174 at 120V AC input