System battery

If the server no longer automatically displays the correct date and time, you may need to replace the battery

that provides power to the real-time clock. Under normal use, battery life is 5 to 10 years.

WARNING:

The computer contains an internal lithium manganese dioxide, a vanadium

pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not

properly handled. To reduce the risk of personal injury:

Do not attempt to recharge the battery.

Do not expose the battery to temperatures higher than 60°C (140°F).

Do not disassemble, crush, puncture, short external contacts, or dispose of in fire or water.

Replace only with the spare designated for this product.

To remove the component:

1.

Power down the server (on page

18

).

2.

Extend or remove the server from the rack ("

Extend the server from the rack

" on page

18

).

3.

Remove the access panel (on page

20

).

4.

If installed, remove the BBWC battery pack or the FBWC capacitor pack (on page

20

).

5.

Remove the air baffle (on page

21

).

6.

Locate the battery on the system board ("

System board components

" on page

10

).

7.

Remove the battery.

IMPORTANT:

Replacing the system board battery resets the system ROM to its default

configuration. After replacing the battery, reconfigure the system through RBSU.