beautypg.com

HP ProLiant DL585 Server User Manual

Page 66

background image

Installing hardware options

HP ProLiant DL585 Server User Guide

4-15



Determining the proper hot-plug SCSI hard drive installation order

The system reads and manages the hot-plug SCSI hard drives based on the SCSI ID
number assigned to each drive. For optimal hard drive management and performance,
install the hard drives in the order of SCSI ID assignments. Always populate hard
drive bays starting with the lowest SCSI ID.

Figure 4-13: Hot-plug SCSI hard drives and SCSI ID
numbers

Table 4-5: Hot-plug SCSI hard drives and SCSI ID numbers

Item

Description

Simplex SCSI ID

Duplex SCSI ID

1

SCSI hard drive 1

0

0

2

SCSI hard drive 2

1

1

3

SCSI hard drive 3

2

0

4

SCSI hard drive 4

3

1

Note: Simplex configuration equals all four drives in the server connected to
one SCSI channel. Duplex configuration equals two drives per SCSI channel.