beautypg.com

HP ProLiant DL585 Server User Manual

Page 150

background image

System LEDs and switches

E-14

HP ProLiant DL585 Server User Guide



Table E-10: QuickFind diagnostic display LEDs

continued

Item Description Status

Action

8

Therm trip

Off = Normal

On = Attention required

The server experienced a thermal
shutdown.

If one of the CPU thermal LEDs is amber,
that CPU experienced an overtemperature
condition.

Be sure that the

processor heatsink is properly
attached. For more information, refer
to the maintenance and service guide.

Be sure the correct

DIMMs (1.2-inch) are installed.

Be sure all fans are

installed and working properly

9

SCSI interlock

Off = Normal

On = Attention required

Ensure the SCSI backplane is installed
properly.

Reseat SCSI backplane board and hard
drives.

10

Power supply 1

Off = Normal

On = Attention required

Look at the LEDs on the front of the power
supply and take the appropriate action.

11

Power supply 2

Off = Normal

On = Attention required

Look at the LEDs on the front of the power
supply and take the appropriate action.

12

Bus error

Off = Normal

On = Attention required

A bus error occurred.

The error might have been caused by one
of the adapter cards on this bus (see amber
LEDs for which slots might have caused
the error).

Reseat the adapter cards.

If problem persists, remove or replace one
or both of the cards.