Redundant rom support, Redundant rom support -12 – HP ProLiant DL585 Server User Manual
Page 109
Server Configuration and Utilities
5-12
HP ProLiant DL585 Server User Guide
5. Exit iLO RBSU.
HP recommends using DNS/DHCP with iLO to simplify installation. If DNS/DHCP
cannot be used, use the following procedure to disable DNS/DHCP and to configure
the IP address and the subnet mask:
1. Restart or power up the server.
2. Press the F8 key when prompted during POST. The iLO RBSU runs.
3. Select Administer User Accounts>Configure iLO Settings. Enter a valid iLO
user ID and password with the appropriate iLO privileges Default account
information is located on the iLO Default Network Settings tag.
4. Select Network>DNS/DHCP, and press the Enter key.
5. Select DHCP Enable. Press the spacebar to turn off DHCP. Be sure that DHCP
Enable is set to Off, and save the changes.
6. Select Network>NIC and TCP/IP, and press the Enter key.
7. Enter the appropriate information in the following fields:
• IP Address
• Subnet Mask
• Gateway IP Address
8. Save the changes. The iLO system automatically resets to use the new setup
when you exit iLO RBSU.
Redundant ROM support
The server enables you to upgrade or configure the ROM safely with redundant ROM
support. The server has 4 MB of ROM that acts as two separate 2-MB ROMs. In the
standard implementation, one portion of the ROM contains the current ROM
program version, while another portion of the ROM contains a backup version.