beautypg.com

HP ProLiant DL585 Server User Manual

Page 165

background image

Troubleshooting

HP ProLiant DL585 Server User Guide

H-7



Table H-3: Is the system power LED green?

Answer Possible

reasons Possible

solutions

No

The Power on/Standby button has not
been pressed firmly.

Firmly press the power button.

A power supply problem exists. The
power supply might not be connected
or inserted properly, it might have a
damaged connector, or it might have
failed.

Be sure that the power supply is
undamaged, the power supply is fully
seated, and the power supply LED is
green.

The system might have experienced a
short.

Look for bent connector pins and
improperly seated expansion boards.

The front panel LED assembly has
failed.

Be sure that the front panel LED
assembly cable is connected to the
power backplane.

If these solutions do not solve the
problem, contact an authorized
service provider for assistance.

Yes

If the system power button LED is
green, refer to Table H-4.

Note: For cabling configurations, refer to Appendix D, “Cabling guidelines.” For LED locations and