System LEDs and switches

HP ProLiant DL585 Server User Guide

E-13



Table E-10: QuickFind diagnostic display LEDs

continued

Item Description Status

Action

3 Processor

memory board

Off = Normal

On = Attention required

Processor memory board power failure. If
problem persists, replace the processor or
processor memory board.

4 Processor

power module

Off = Normal

On = Attention required

PPM power failure. If problem persists,
replace PPM.

If the PPM and the BRD LEDs are both on,
there is a configuration error.

5 Temperature

Off

=

Normal

On = Attention required

One or more components have
experienced an elevated temperature or a
thermal shutdown.

A thermal shutdown is indicated by the
Therm Trip LED.

Be sure the processor

heatsink is properly attached.

Be sure there are no 1.7"

DIMMs installed that prevent airflow
across the processor heatsink).

Be sure that all fans are

installed and working properly.

Be sure that the server

environment meets posted
requirements.

For information about server environment
requirements refer to the “Optimum
environment” section in Chapter 3.

6 DIMM

Off

=

Normal

On = Attention required

DIMM failure or configuration error. Refer to
the IML or POST messages

7

I/O power fault

Off = Normal

On = Attention required

A power fault on the system I/O board
occurred. If problem persists, replace the
system I/O board.