beautypg.com

HP ProLiant DL585 Server User Manual

Page 158

background image

Server specifications

G-2

HP ProLiant DL585 Server User Guide



Table G-1: Server specifications

continued

Feature Units

Power supply output power

Rated steady-state power

800 W

Maximum peak power

800 W

Temperature range

Operating

10

°

to 35

°

C (50

°

to 95

°

F)

Non-operating

-30

°

to 60

°

C (-20

°

to 140

°

F)

Relative humidity (non-condensing)

Operating

20% to 80%

Non-operating

5% to 90%

Maximum wet bulb temperature

38.7

°

C (101.7

°

F)

Heat dissipation

3900 BTU/Hr