Problems after initial boot – HP ProLiant DL585 Server User Manual
Page 171
Troubleshooting
HP ProLiant DL585 Server User Guide
H-13
Problems after initial boot
After the server has passed POST, you might still encounter errors, such as an
inability to load the operating system. Use Table H-7 to troubleshoot server
installation problems that occur after the initial boot.
Refer to the HP Servers Troubleshooting Guide for more information.
Table H-7: Problems after initial boot
Problem Possible
reasons Possible
solutions
ProLiant Essentials
Foundation Pack requirement
not performed.
Check the ProLiant Essentials Release Notes
provided in the ProLiant Essentials Online
Reference Information on the ProLiant
Essentials Foundation Pack.
CD-ROM drive is not properly
seated.
Reseat CD-ROM drive.
Insufficient memory is
available.
A rare Insufficient Memory message might
display the first time ProLiant Essentials is
booted on certain unconfigured systems. Cold-
boot the machine with the ProLiant Essentials
Foundation Pack inserted in the CD-ROM drive
to correct the problem.
System cannot
load ProLiant
Essentials
Foundation
Pack.
Existing software is causing
conflict.
Run the System Erase Utility. Read the
Caution at the end of the table. Refer to the
instructions in the HP Servers Troubleshooting
Guide.
continued