8 Alarm Control and Audible
Warnings
HP NetRAID Series adapters have onboard tone generators that indicate events
and errors.
NOTE
The integrated HP NetRAID controller does not have alarm
control or audible warnings.
Table 8-1. Audible Warnings
Tone Pattern
Meaning
Examples
Three seconds on
and one second off
A logical drive is offline.
One or more drives in a RAID 0
configuration failed.
Two or more drives in a RAID 1, 3,
5, 10, 30, or 50 configuration failed.
One second on
and one second off
A logical drive is running
in degraded mode.
One drive in a RAID 3, 5, 30, or 50
configuration failed.
One second on
and three seconds
off
An automatically initiated
rebuild has been
completed.
While you were away from the
system, a disk drive in a RAID 1, 3,
5, 10, 30, or 50 configuration failed
and was rebuilt.
To silence a sounding alarm (or to disable or enable the alarm), you must use the
Alarm Control selection in one of the HP NetRAID management utilities. To
reach the Alarm Control setting do the following:
•
In HP NetRAID Assistant, select the Adapter menu, then Alarm Control.
•
In HP NetRAID Config, select Objects, then Adapter, then Alarm
Control.
•
In HP NetRAID Express Tools, select Objects, then Adapter, then Alarm
Control.
Alarm Control has two options:
•
Enable/Disable Alarm: Choose this option to enable or disable the
onboard tone generator. The default setting is Enabled.
•
Silence Alarm: This setting stops the alarm when it goes off.