Chapter 5
Reconstructing and Rebuilding Drives
106
2. Choose Rebuild from the Management menu. A device selection window
is displayed showing the devices connected to the current adapter. The
failed drives have FAIL indicators.
3. Use the arrow keys to highlight the first physical drive to be rebuilt then
press the Spacebar to select it.
4. Use the arrow keys and Spacebar to select any additional physical drives to
be rebuild.
5. Press F10 and type Yes at the confirmation prompt. The indicators for the
selected drives change to REBLD.
6. When the rebuild is complete, press any key to continue. Press Esc to
return to the Management menu.
Manual Rebuild from HP NetRAID Express Tools (under any NOS)
1. Log off all users, close all applications, and power down the HP NetServer.
2. Restart the server. Look for the following prompt during startup:
Option: Experienced users may press
HP NetRAID Express Tools now.
Firmware Initializing
3. Press <Ctrl> <M>. When the system stops scanning, HP NetRAID
Express Tools starts.
4. Choose Rebuild from the Tools Management menu.
5. Use the arrow keys to highlight one or more physical drives to be rebuilt.
6. Use the Spacebar to select (or deselect) the drive to be rebuilt.
7. Press F10 to start the rebuilding process.