HP NetRAID 1Si Controller User Manual
Page 107

Chapter 5
Reconstructing and Rebuilding Drives
101
2. Restart the HP NetServer. Look for the following prompt during startup:
Option: Experienced users may press
HP NetRAID Express Tools now.
Firmware Initializing
3. Press <Ctrl> <M>. When the system stops scanning, HP NetRAID
Express Tools starts.
4. Choose Objects from the Tools Management menu.
5. Choose Adapter from the Objects menu.
6. If you have more than one adapter, select the adapter for which you want to
change the PFS setting.
7. Choose Power Fail Safeguard from the Adapter menu.
8. If you want to change the PFS setting on another adapter, press Esc to
return to the Objects menu. Then repeat Steps 4 through 7 for that adapter.
9. When you have changed the PFS settings on all adapters, press Esc
repeatedly to return to the Tools Management menu.
10. To exit HP NetRAID Express Tools, press Esc at the Tools Management
menu. Choose Yes at the prompt. You must then restart the HP NetServer.
Using HP NetRAID Config to Change the PFS Setting
To change the PFS setting by using the HP NetRAID Config utility:
1. Start HP NetRAID Config by using the command appropriate for your
network operating system.
2. Choose Objects from the Management menu.
3. Choose Adapter from the Objects menu.
4. If you have more than one adapter, select the adapter for which you want to
change the PFS setting.
5. Choose PowerFail Safeguard from the Adapter menu.
6. If you want to change the PFS setting on another adapter, press Esc to
return to the Objects menu. Then repeat Steps 3 through 5 for that adapter.
7. When you have changed the PFS settings on all adapters, press Esc
repeatedly to return to the Management menu. You do not need to restart
the server for this parameter to take effect.