Measure Command Interface (MEASCOM)
Measure User’s Guide — 520560-003
2- 10
Accessing Online Help
process whose programfile was in $SYSTEM.SYSTEM to be
measured. To view the measurement configuration for each
entity type use the INFO entity command. Once the
configuration is complete, a START MEASUREMENT command is
executed.
To view the results of the measurement the ADD
MEASUREMENT command is used (the START and STOP MEASUREMENT
commands perform an implicit ADD MEASUREMENT). This
operation starts a MEASURE file handler process (MEASFH)
which is used to retrieve the data stored in the file. To
view the data, use the LIST or LISTALL entity commands.
After a LIST command, the ADD PLOT command can be used to
add counters to the current plot list. For each ADD PLOT,
one or more entities are added to the list, along with the
counter of interest. To display the PLOT, use the LIST PLOT
command.
For specific command syntax perform:
++
HELP ADD ENTITY (for general syntax)
HELP ADD <entity type> (e.g.HELP ADD CPU, for specific
syntax)
HELP ADD MEASUREMENT
HELP ADD PLOT
•
To get command syntax information, enter HELP, the command, and the object:
33+ HELP ADD MEASUREMENT
ADD [ MEASUREMENT ] < filename> [, MEASFH <filename> ]
If either <filename> is a logical Define name, the define
must exist, and map to a permanent disk filename.
•
If the command object is an entity type, you can get both general syntax
information and entity-specific syntax information. To get general syntax, enter
HELP, the command, and ENTITY. For example:
34+ HELP LIST ENTITY
LIST [ ] ...
where is:
{ IF
{ BY
{ FROM