Starting and Stopping MEASCOM

To list the currently active measurements before stopping the Measure subsystem:

43> MEASCOM
MEASURE Performance Monitor - T9086G10 - (16DEC03) - \HATI
(C)1986 Tandem (C)2003 Hewlett Packard Development Company, L.P.
1+ STATUS MEASSUBSYS
Number of Active (or Configured) Measurements = 0
2+ STOP MEASSUBSYS

If you enter the STOP MEASSUBSYS command from an interactive MEASCOM
session and measurements are active, this prompt appears:

n measurement(s) still active; still stop the subsystem (y/n)?

A YES response aborts all active measurements before the subsystem is stopped. If
transient entities do not exist or the measurement was run without a collection interval,
the records are lost. Closing records are not written when a measurement is aborted. A
NO response cancels the STOP MEASSUBSYS command.

Starting and Stopping MEASCOM

Use the TACL RUN command to start the MEASCOM command interpreter process.

where:

RUN $disk.subvol

is required only if MEASCOM is not located in $SYSTEM.SYSTEM or
$SYSTEM.SYS

nn

.

To stop a MEASCOM session:

10+ EXIT
4>

14> [ RUN $disk.subvol ] MEASCOM