HP Integrity rx2660 Servers User Manual
Page 77
Scripted deployment 77
Parameter
Description
Possible values
REBOOTALLOWED
This parameter enables you to reboot, if
required.
YES, NO
REBOOTMESSAGE
This parameter enables you to create a message
to be displayed prior to rebooting.
Any string (not exceeding
256 characters)
REBOOTDELAY
This parameter enables you to delay before
rebooting.
Time in seconds
COMPONENTSLIST
This parameter enables you to limit the list of
components to be updated.
Component names with
file extensions (.exe,
.rpm, or .scexe)
BUNDLESLIST
This parameter enables you to limit the list of
bundle xml files to be filtered.
Bundle file names
ALLOWUPDATEBUNDLE
This parameter is a filter switch and enables you
to install newer versions of components defined
in a PSP, ISP, or bundle.
This parameter enables these components to
replace the older versions of the same
component that might have shipped with the
bundles.
YES, NO
SKIPTARGET
This parameter defines the behavior when a
remote target has an existing HP SUM session in
progress.
This parameter enables you to skip the host if an
existing HP SUM session already exists. A NO
overrides the session in progress and reinitializes
the installation framework on the remote host.
YES, NO
IGNOREERRORS
This parameter causes the installation to continue
and ignore errors.
The ServerNotFound option can be used to
bypass inactive or unavailable remote hosts
when deploying firmware or software to multiple
remote hosts at the same time.
FailedDependencies can be used to ignore any
failed dependencies and proceed with the ones
that are ready to be installed.
ServerNotFound,
BadPassword,
FailedDependencies
SOURCEPATH
This parameter can be used to provide a single
local repository path. This creates an inventory
from the given path instead of the local or
default repository.
Directory path
USELATEST
This parameter is a filter switch for use with
bundles. The parameter enables you to use the
latest version of the bundle when multiple
versions of bundles are listed on the command
line.
If no bundles are specified on the command line,
and multiple bundles are in the directory, then
this parameter enables HP SUM to use the
bundle with the latest version for installation.
YES, NO
DRYRUN
This parameter simulates the installation for a test
run. Nothing is installed.
YES, NO
- Integrity rx7640 Server Integrity rx3600 Server Integrity BL870c Server-Blade Integrity BL860c Server-Blade Integrity BL860c i2 Server-Blade SmartStart-Software Integrity rx2800 i2 Server Integrity rx6600 Server Integrity rx8640 Server Integrity Superdome sx2000 Server Integrity BL870c i2 Server-Blade