Troubleshooting hp, Smart update manager in ipv6 networks, Troubleshooting hp smart – HP Integrity rx2660 Servers User Manual
Page 107: Update manager in ipv6 networks
Troubleshooting 107
Recovering a lost HP Smart Update Manager
connection
HP Smart Update Firmware DVD mounted using iLO virtual
media
When either iLO and NIC firmware are updated, the HP SUM connection is lost and cannot install
components.
Booting the Firmware DVD from iLO virtual media is only supported in Offline Automatic Firmware
Update mode. Users attempting to boot in this manner might experience issues from connection timeouts,
difficulties updating iLO firmware, and mouse syncing issues. If an access error exists, HP SUM cancels
the installation.
Troubleshooting HP Smart Update Manager in IPv6
networks
If HP Smart Update Manager cannot connect to the remote server, you might receive a Discovery Failed
error. Discovery failures can be caused by third-party storage, failure to access the remote target server,
and an inability to access system resources. For IPv6 networks, host discovery failures can be caused by
the incorrect configuration of the IPv6 network.
Troubleshooting HP Smart Update Manager in IPv6 Windows
Server 2003 environment
To validate that the IPv6 network is configured correctly for HP Smart Update Manager support, you must
verify the following based on your operating system version.
•
Validate that the addresses are site-local. Site-local addresses normally start with "FEC0:". Global
and link-local IPv6 addresses are not supported when the remote target is Windows Server® 2003.
•
Validate that you can ping the remote target server. With Windows® operating systems, you can
still use the ping command to ping IPv6 addresses: ping
•
Ensure you can ping the IPv6 loopback address: ping ::1.
•
Use the DNS hostname instead of IPv6 address to ensure the address is correct.
•
Ensure you have installed the IPv6 protocol. It is not installed by default in Windows Server® 2003.
Be sure to reboot the server after installing the protocol to ensure addresses are properly obtained.
•
Verify that you can connect to the admin$ share using the credentials within HP Smart Update
Manager by issuing the following command at a console prompt:
net use * \\
net use * \\fec0::2.ipv6-literal.net\admin$ /user:administrator
You might need to provide the password if you are using a user name that is not the same as you
used to log in to the local system. All network shares require the use of the .ipv6-literal.net name
string to be properly configured by Windows®.
- Integrity rx7640 Server Integrity rx3600 Server Integrity BL870c Server-Blade Integrity BL860c Server-Blade Integrity BL860c i2 Server-Blade SmartStart-Software Integrity rx2800 i2 Server Integrity rx6600 Server Integrity rx8640 Server Integrity Superdome sx2000 Server Integrity BL870c i2 Server-Blade