beautypg.com

Hp sum hangs during discovery, Configuring firewall settings – HP Integrity rx2660 Servers User Manual

Page 102

background image

Troubleshooting 102

In rare cases, external storage enclosures might cause HP SUM to report a discovery failure or to

hang. To resolve this issue, disconnect the external storage until the firmware updates are completed.

For Linux, ensure that the target server can be contacted through SSH and that the scp command is

available to securely send files to the target server.

Ensure the firewall ports on any routers in the network as documented in the Enabling ports in HP

Smart Update Manager section of this document.

The SEP product blocks HP SUM ability to communicate with remote targets if the Network Threat
Analysis feature is enabled. Disable this feature while HP SUM is in use on the workstation.

Examine the OpMan.trace, IPScout.trace, OSScout.trace, discagent.trace, and discmanager.trace
files to determine the cause of the failure. For more information, see "Collecting trace directories (on

page

100

)".

Ensure the server has a valid serial number.

HP SUM hangs during discovery

If a system hang is observed during HP SUM discovery and the system is connected to external storage, in

most cases disconnecting the external storage should resolve the issue.

Recovering from a loss of Linux remote functionality

Configuring firewall settings

When the Unable to Access Host message appears, the target firewall is enabled. By default, the

target firewall is enabled in Linux.
To recover remote Linux functionality, the target and host firewall must be disabled or reconfigured to

allow IP traffic through the ports needed by HP Smart Update Manager to deploy firmware. For a list of

the ports that need to be configured in the firewall, see Allowing ports in HP Smart Update Manager
("

Enabling ports in HP Smart Update Manager

" on page

103

).