Recovering from an installation failure, Collecting trace directories – HP Integrity rx2660 Servers User Manual
Page 100
Troubleshooting 100
Recovering from an installation failure
Collecting trace directories
HP Smart Update Manager generates a set of debug trace logs located in the %TEMP%\hp_sum directory
on Windows systems and \tmp\hp_sum on Linux systems. These files contain internal process and debug
information, which can be useful in determining HP Smart Update Manager failures.
NOTE:
To break out to a Linux console while booted to the HP Smart Update Firmware DVD,
press Ctrl Alt d b x. Each key (d, b, x) is hit in succession. This command allows you to collect
logs from the \tmp\hp_sum directory.
Examine the OpMan.trace, IPScout.trace, OSScout.trace, InstallClient.log, and InstallManager.log trace
files to determine the cause of the failure. These files provide the following information.
Trace files
Function
OpMan.trace
Provides operations trace of the overall installation process.
IPScout.trace
Provides the information on whether the remote target might be contacted and the
type of target found (iLO, server, VC, OA).
OSScout.trace
Provides the details of the connection setup and is responsible for cleaning up after
an installation and initiating a reboot, if needed and selected by the user, on the
target system.
InstallClient.log
Provides the details of the execution of the individual components, including the
command line parameters, used to launch the components and the component
return code before it is converted to HP Smart Update Manager return codes.
InstallManager.log
Provides the interaction between the Operations Manager and the remote
installation client. Any failure in network communications is reported in this file and
surfaced as an Installation Failed message for the affected component and
potentially all components that follow the failing component.
discagent.trace
Provides the details of the execution of the discovery agent on either the local
system during a local installation or the remote target server. If a discovery tool
fails, it is reported to this trace file and surfaced as a Discovery Failed message.
discmanager.trace
Provides the interaction between the Operations Manager and the remote
discovery client. If a discovery tool fails, it is reported to this trace file and surfaced
as a Discovery Failed message.
It is possible to look in the OpMan.trace file and see which component was winnowed from the
installation set and which ones were added. Normally, components are winnowed if:
•
They do not support installation on the given OS
•
The hardware they are designed for is not discovered to be present in the server
•
The component is not for the type of target selected
•
The component does not report itself capable of being deployed to a given target
•
The component cannot be deployed in either the online or offline environment HP Smart Update
Manager detects it is running in
•
The component is for a particular class (p-Class or c-Class) of BladeSystem enclosure and the
component does not find that class of enclosure.
- Integrity rx7640 Server Integrity rx3600 Server Integrity BL870c Server-Blade Integrity BL860c Server-Blade Integrity BL860c i2 Server-Blade SmartStart-Software Integrity rx2800 i2 Server Integrity rx6600 Server Integrity rx8640 Server Integrity Superdome sx2000 Server Integrity BL870c i2 Server-Blade