HP Integrity rx2660 Servers User Manual
Page 108
Troubleshooting 108
NOTE:
You do not need to use the .ipv6-literal.net suffix when entering IPv6 address into the
HP Smart Update Manager user interface or when passing IPv6 address using command line
parameters to HP Smart Update Manager.
After you validate that you can access the admin$ share on the remote target server, HP Smart
Update Manager works unless other network or hardware issues exist.
•
Ensure you have made the registry change on remote target servers as mentioned in the HP Smart
Update Manager Usage in a Windows Server® 2003 IPv6 environment ("
" on page
•
Move back to an IPv4 network address to ensure HP Smart Update Manager properly finds the
remote target server without any issues.
You can always copy HP Smart Update Manager to the target servers and execute using the local
installation method.
Troubleshooting HP Smart Update Manager in IPv6 Windows
Server 2008 environment
To validate that the IPv6 network is configured correctly for HP Smart Update Manager support, you must
verify the following based on your operating system version.
•
Validate that you can ping the remote target server. With Windows® operating systems, you can
use the ping command to ping IPv6 addresses: ping
•
Ensure you can ping the IPv6 loopback address: ping ::1.
•
Use the DNS hostname instead of IPv6 address to ensure the address is correct.
•
Verify that you can connect to the admin$ share using the credentials within HP Smart Update
Manager by issuing the following command at a console prompt:
net use * \\
net use * \\fec0::2.ipv6-literal.net\admin$ /user:administrator
You might need to provide the password if you use a user name that is different from the one you
used to log in to the local system. All network shares require the use of the .ipv6-literal.net name
string to be properly configured by Windows®.
After you validate you can access the admin$ share on the remote target server, HP Smart
Update Manager works unless there are other network or hardware issues.
Troubleshooting HP Smart Update Manager in IPv6 Red Hat and
Novell SUSE-based Linux environments
•
Verify that you can establish an SSH connection to the remote target server using the credentials
within HP Smart Update Manager by issuing the following command at a console prompt:
ssh
SSh 2101:db8:0:1::9
You must enter the root password for the target Linux server at the console to complete the IPv6
connection.
•
Validate that you can ping the remote target server. In Linux, you need to use the ping6 command to
ping IPv6 addresses: ping6
- Integrity rx7640 Server Integrity rx3600 Server Integrity BL870c Server-Blade Integrity BL860c Server-Blade Integrity BL860c i2 Server-Blade SmartStart-Software Integrity rx2800 i2 Server Integrity rx6600 Server Integrity rx8640 Server Integrity Superdome sx2000 Server Integrity BL870c i2 Server-Blade