Scripted deployment 70

Command-line

argument

Description

/current_credential This argument enables the credentials of the local host to be used as the

credentials to access the targets instead of providing the username and

password explicitly for each target. The assumption is that the current

credentials are valid for the targets being accessed. (Applies to Windows®
operating systems only.)

/target "netAddress"

This argument is the IP address or the DNS name of a remote server, remote
iLO NIC port, Virtual Connect Ethernet or Fibre Channel Module for c-Class

BladeSystem, or BladeSystem Onboard Administrator.
When two Onboard Administrators are in an enclosure, this argument should
be the active Onboard Administrator. When specifying the IP address, you

can use either the IPv4 or IPv6 format.

/oa_username

username>

This argument provides the username credential for OA associated with VC
specified with "target" command-line parameter. Only one set of OA

credentials can be specified with command-line parameters. You can only
add multiple VC targets to command-line parameters with "target" parameter

if the credentials of OAs associated with specified VCs are the same. The
argument oa_username is not required if VC has the same credentials as

the associated OA. You do not need to provide an OA network address

associated with Virtual Connect. HP SUM queries it from a specified VC
target.
To update multiple VCs with different username and password or VCs with
OAs which have different credentials, the corresponding input files OAUID

(for OA username) and OAPWD (for OA password) must be used.

/oa_password

password>

This argument provides the username credential for OA associated with VC
specified with "target" command-line parameter. Only one set of OA

credentials can be specified with command-line parameters. You can only

add multiple VC targets to command-line parameters with "target" parameter
if the credentials of OAs associated with specified VCs are the same. The
argument oa_password is not required if VC has the same credentials as

the associated OA. You do not need to provide an OA network address

associated with Virtual Connect. HP SUM queries it from a specified VC
target.
To update multiple VCs with different username and password or VCs with
OAs which have different credentials, the corresponding input files OAUID

(for OA username) and OAPWD (for OA password) must be used.

Log files

/logdir "path"

This argument enables you to redirect the output from HP SUM or the HP

BladeSystem c-Class Onboard Administrator flash utility to a different
directory than the default location.

For Windows® components, the default location is

%SYSTEMDRIVE%\CPQSYSTEM\hp\log and the redirected
location is \hp\log\.

For Linux components, the default location is /var/hp/log/

and the redirected location is /hp/log/.

/v[erbose] or

/veryv[erbose]

These arguments enable you to set the verbosity level for the HP SUM
execution log file, hpsum_execution_log__. Using one of

these arguments increases the level of detail that is retained in the log file.
The default value is normal verbosity.

Generating reports