beautypg.com

HP StorageWorks Modular Arrays User Manual

Page 45

background image

Troubleshooting 4-15

Compaq Confidential – Need to Know Required

Writer: Bill Reitz Project: Compaq StorageWorks 64-Bit PCI-To-Fibre Channel Host Bus Adapter User Guide Comments:

Part Number: AA-RKPDA-TE 173941-001 File Name:

E-CH4 TROUBLESHOOTING.DOCe-ch4 Troubleshooting.doc

Last Saved On:

12/22/99 10:10

AM12/20/99 6:07 PM

Table 4-5
Current Private Loop Device Mapping

continued

Bus #
0

Target#
0-31

Lun#
0-7

*AL_PA
None

*SEL_ID
None

**AL_PA
None

**SEL_ID
None

6

0-7

0xBA

0x1A

0x35

0x63

7

0-7

0xBC

0x19

0x34

0x64

8

0-7

0xC3

0x18

0x33

0x65

9

0-7

0xC5

0x17

0x32

0x66

10

0-7

0xC6

0x16

0x31

0x67

11

0-7

0xC7

0x15

0x2E

0x68

12

0-7

0xC9

0x14

0x2D

0x69

13

0-7

0xCA

0x13

0x2C

0x6A

14

0-7

0xCB

0x12

0x2B

0x6B

15

0-7

0xCC

0x11

0x2A

0x6C

16

0-7

0xCD

0x10

0x29

0x6D

17

0-7

0xCE

0x0F

0x27

0x6E

18

0-7

0xD1

0x0E

0x26

0x6F

19

0-7

0xD2

0x0D

0x25

0x70

20

0-7

0xD3

0x0C

0x23

0x71

21

0-7

0xD4

0x0B

0x1F

0x72

22

0-7

0xD5

0x0A

0x1E

0x73

23

0-7

0xD6

0x09

0x1D

0x74

24

0-7

0xD9

0x08

0x1B

0x75

25

0-7

0xDA

0x07

0x18

0x76

* Use this translation if registry ScanDown = 0 (default)

** Use this translation if registry ScanDown = 1

*** If MapBus0=1;, then device addressing starts with Bus #0, not #1