HP StorageWorks Modular Arrays User Manual
Page 43
Troubleshooting 4-13
Compaq Confidential – Need to Know Required
Writer: Bill Reitz Project: Compaq StorageWorks 64-Bit PCI-To-Fibre Channel Host Bus Adapter User Guide Comments:
Part Number: AA-RKPDA-TE 173941-001 File Name:
E-CH4 TROUBLESHOOTING.DOCe-ch4 Troubleshooting.doc
Last Saved On:
12/22/99 10:10
AM12/20/99 6:07 PM
Table 4-5
Current Private Loop Device Mapping
continued
Bus #
0
Target#
0-31
Lun#
0-7
*AL_PA
None
*SEL_ID
None
**AL_PA
None
**SEL_ID
None
3***
0
0-7
0x73
0x3F
0x74
0x3E
1
0-7
0x74
0x3E
0x73
0x3F
2
0-7
0x75
0x3D
0x72
0x40
3
0-7
0x76
0x3C
0x71
0x41
4
0-7
0x79
0x3B
0x6E
0x42
5
0-7
0x7A
0x3A
0x6D
0x43
6
0-7
0x7C
0x39
0x6C
0x44
7
0-7
0x80
0x38
0x6B
0x45
8
0-7
0x81
0x37
0x6A
0x46
9
0-7
0x82
0x36
0x69
0x47
10
0-7
0x84
0x35
0x67
0x48
11
0-7
0x88
0x34
0x66
0x49
12
0-7
0x8F
0x33
0x65
0x4A
13
0-7
0x90
0x32
0x63
0x4B
14
0-7
0x97
0x31
0x5C
0x4C
15
0-7
0x98
0x30
0x5A
0x4D
16
0-7
0x9B
0x2F
0x59
0x4E
17
0-7
0x9D
0x2E
0x56
0x4F
18
0-7
0x9E
0x2D
0x55
0x50
19
0-7
0x9F
0x2C
0x54
0x51
* Use this translation if registry ScanDown = 0 (default)
** Use this translation if registry ScanDown = 1
*** If MapBus0=1;, then device addressing starts with Bus #0, not #1
continued