Table 4-1
HBA POST LED States
Green LED
Yellow LED
Description
Off
Off
Wake-up failure (inoperable HBA)
Off
On
POST failure (inoperable HBA)
Off
Slow blink (1 Hz)
Wake-up failure
Off
Fast blink (4 Hz)
Failure in POST
Off
Flashing (irregular)
POST processing in progress
On
Off
Failure while functioning
On
On
Failure while functioning
On
Slow blink (1 Hz)
Normal (inactive)
On
Flashing (irregular)
Normal (active)
On
Fast blink (4 Hz)
Normal (busy)
Slow blink
Off
Normal (link down or not yet started)
Slow blink
Slow blink (1 Hz)
Off-line for download
Slow blink
Fast blink (4 Hz)
Restricted off-line mode (waiting for restart)
The Windows NT Event Viewer
The Windows NT SCSI driver verifies the condition of the HBA POST. If
there is a failure or a suspected failure, an error log entry is issued to the
Windows NT System Event Logger (Viewer).
Following is the procedure for viewing the Windows NT error log.
From the Main menu:
1.
Double click or select the Administrative Tools program group.
2.
Double click or select the Event Viewer. The display shows a list of
discrete events specifying the source name LP8NDS35 (NT SCSI
driver).
3.
Double click any event with the source name LP8NDS35.