beautypg.com

Connecting xp1024/xp128 disk arrays – HP XP Data Shredder Software User Manual

Page 153

background image

Table 21 Path status and examples of recovery procedures (XP12000/XP10000

Disk Arrays)

Path status

Examples of recovery procedures

LUN Manager may have changed the LU paths' settings.
Check the LU paths' settings. If the LU paths' settings changed, change

the settings back to the ones used when the volume was mapped.

Or use External Storage XP to perform the Delete LU operation, and

perform the Add LU operation again.

External device setting changed

LUN Security XP Extension may have changed the volume's access

attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, Continuous Access XP Journal, or another copy

program. If the volume is set as a pair volume, the volume might be

protected because of the pair status. If the volume is protected, change

the pair status or delete the pair.

Illegal request

LUN Security XP Extension may have changed the volume's access

attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
The volume may have been set as a pair volume for data copy.
Check if the volume is set as a pair volume for Business Copy XP,

Continuous Access XP, Continuous Access XP Journal, or another copy

program. If the volume is set as a pair volume, the volume might be

protected because of the pair status. If the volume is protected, change

the pair status or delete the pair.

Response error

LUN Security XP Extension may have changed the volume's access

attribute.
Check the volume's access attribute. If the volume is protected by the

access attribute, release the protection.
There is a problem with the connection to the external array. The

following are possible causes:

The fibre cable is not connected properly.

The topology setting between the external and target ports does

not match.

If the external array is connected through switches, the switches'

settings might not be appropriate.

Check if the fibre cable is connected properly, and use LUN

Management to set the Fibre Channel port properly.

Cannot detect port

LUN Management may have enabled LUN security.
Check if LUN security is enabled. If LUN security is enabled, disable

LUN security.

Connecting XP1024/XP128 Disk Arrays

When connecting an XP1024/XP128 Disk Array as the external array, you must set the external array

port host group for one of two types of Windows hosts (host mode 0C: Windows, host mode 2C:

Windows Extension).
Also, the port attribute must be the target or RCU target port.

External Storage XP user guide

153