beautypg.com

HP XP Data Shredder Software User Manual

Page 140

background image

Error

Corrective action

Internal error

Status: A program error occurred, or there is a

logical contradiction.
Corrective action: Contact your HP account support

representative.

Timeout

Status: Processing was retried because an abnormal

reply (Response) was returned, but processing has

stopped due to a timeout.
Corrective action: The external array's port of is

recognized. Check the condition of the connection

(for example, cables and switches) to the external

array. If you cannot restore the path, contact your

HP account support representative.

Target error

Status: An error, such as blockade of the controller,

was found in the external array's port.
Corrective action: Check the status of the external

array's ports. If you cannot restore the path, contact

your HP account support representative.

Unavailable

Status: The reply from the external array was

Unavailable. The external array requested a change

to the connected port. When the status becomes

Unavailable, the primary path changes to the

alternate path that is in Standby status. When the

primary path changes, the path status becomes

Normal.
Corrective action: If the path does not change

properly, check the external array's status. If you

cannot restore the path, contact your HP account

support representative.

Backoff

Status: The reply from the external array was Backoff.

The path status is Waiting for Recovery because

a temporary error occurred in the external array's

volume. Even if the primary path's status becomes

Backoff, the primary path does not change to the

alternate path immediately. After error recovery, the

status becomes Normal.
Corrective action: If you cannot recover the status

from the error, the path status changes to another

status. Take the corrective action for the new path

status. If you cannot restore the path, contact your

HP account support representative.

The Discovery operation

cannot be performed.

Correct the error and retry the operation.
The source of the error could be one of the following:

Command View XP or XP Remote Web Console is not in Modify mode.

The local array port and external array port are not connected using FC

cables.

Port security is improperly set on the external array.

The status of the device in the external array is not Normal.

The external array is not connected to a local array port set to External.

The external LUN of the local array does not have a status of Normal.

The external LU capacity is insufficient (less than 46.86 MB).

The cable to the switch is not properly connected.

The zoning for the switch is not set properly.

If none of these correct the problem, disconnect and then reconnect the cable

between the local array and external array. After 30 seconds, retry the operation.

140

Troubleshooting External Storage XP