beautypg.com

HP XP Data Shredder Software User Manual

Page 141

background image

Error

Corrective action

The external LU is

blocked.

Correct the error and retry the operation. The source of the error could be any

one of the following:

All set paths are blockaded (or not connected).

The external LU's attribute is not set to Read/Write.

The external LU is blockaded by an error.

The Check Paths &

Restore Vol. command

has executed and you

have waited more than

10 minutes, but the

device's status does not

change from Checking.

Click Refresh (

) on the Command View XP or XP Remote Web Console pane

to update the displayed information.
If the device status remains Checking, even though you updated the information,

execute the Check Paths & Restore Vol. command again. If the problem persists

despite retrying, contact your HP account support representative.

The Disconnect

Subsystem or Disconnect

Volume command

has executed, but

the progress status

information is not

updated.

Click Refresh (

) on the Command View XP or XP Remote Web Console pane

to update the displayed information. If the progress information for the Cache

Destage status is not updated, even though you updated the information contact

your HP account support representative.

NOTE:

The time required to write of data from cache to the external LU (destaging

processing) depends on the volume capacity (more time is required for a

larger volume than a smaller one). The processing speed is about 20 MB/s.

However, processing speed depends on the external array's performance

and status.

The message
INTERVENTION

REQUIRED is issued

to the mainframe host as

the device status.

The device status is currently changing. Please wait for a while, and then check

the device status again. When the transition of the device status completes

normally, the device can be used immediately. If the device is blocked as a

result of the device status transition, see the description for the “The external LU

is blocked.” error in this table for corrective action.

The message DEVICE

ERROR is issued to the

mainframe host as the

device status.

See the description for the “The external LU is blocked.” error in this table for the

corrective action.

External Storage XP user guide