beautypg.com

HP Integrity rx4640 Server User Manual

Page 71

background image

Smart Component information is not available without a direct Internet connection

Issue: Smart Component information is not available when the SMS server is connected through a DMZ

(a computer acting as a buffer between the server and the outside public network) to the FTP site. The

HTML file containing the software component information is referenced to the FTP site URL. If there is no

direct internet connection with the computer on which the component is installed, the component

description will be unavailable.
Workaround: None, informational only.

IA-64 and x64 platforms must be selected manually when creating a custom
package using the DSUW

Issue: When you create a custom package for IA-64 or x64 systems using the DSUW for component or

support pack updates, you must select the IA-64 or x64 platforms manually.
Workaround: In the SMS Administrator Console:

1.

Select System Management Server>Site Database>Packages>Programs.

2.

Right-click Programs, and select Properties.

3.

In the Requirements tab, select This program can run only on specified client platforms.

4.

Select the following checkboxes:

All IA64 Windows Server 2003 for IA64 system

All x64 Windows Server 2003 for x64 system

The Software Update status for components does not reflect newly installed
hardware

Issue: The scan tool can only detect the component status if the software and hardware are installed.

The scan tool cannot report status for hardware without HP software installed.
Workaround: Always install the entire support pack to ensure that required software is installed for all

supported devices.

Compliant status for support packs might not reflect actual system status

Issue: The scan tool can only detect status for components that are currently installed. The Compliant

status for the support pack might not reflect the actual system status. The scan tool reports Compliant status

for the support pack if all installed and detected component statuses are compliant.
Workaround: Always install the entire support pack to ensure required software is installed for all

supported devices.

Log files in 64-bit managed system contains incorrect path information

Issue: Log files generated by the scan tool contain incorrect path information when running on 64-bit

operating system. By default, 64-bit Windows® operating systems enable Directory Redirection for

several system directories, causing the scan tool to report incorrect information for some paths.
Workaround: None.

Troubleshooting 71