Command warning messages – HP Matrix Operating Environment Software User Manual
Page 170

Table G-1 Error Messages and Their Correction (continued)
To correct
Possible cause
Message
• Check that the server is up, and
start a new collection.
• Check that the workload is still
associated with the same system (is
Capacity Advisor information
up-to-date).
• Run vseassist to troubleshoot
connection errors.
• A system may have been down
during the collection period.
• The workload may have been
moved since the last automatic
update in Capacity Advisor
(update occurs every 5
minutes).
Error collecting utilization data for
whole-OS workload "system-name" -
some data collected.
or
Error collecting utilization data for
workload "workloadname" on
"system-name" - some data collected.
or
Error collecting physical CPU utilization
data for HPVM "vm-host" from HPVM
Host "vm-name" - some data collected.
Ensure that the node is licensed, and
that appropriate permissions for the
node are set. Run vseassist to
troubleshoot connection errors. You
can also check the configuration of the
system(s) in the Insight managed
system setup wizard.
Permissions for this node are not
in place.
Error: Missing Capacity Advisor
authorization for node: system_name
Ensure that the system where the
workload is running has appropriate
authorization or credentials, then
collect data on that system again. Run
vseassist
to troubleshoot connection
errors. You can also check the
configuration of the system(s) in the
Insight managed system setup wizard.
Missing authorization or
credentials for a system.
Error: No data has been collected for the
specified workload.
Check access and process activity. Run
vseassist
to troubleshoot connection
errors.
See message text.
system_name: Another HP SIM Central
Management Server may be accessing
this system. CIM_ERR_NOT_FOUND:
The requested object could not be found:
Instance not found for RpID: FSS_3 and
datetime: date_time, GUID: n.
Run vseassist to troubleshoot
connection errors.
See message text.
system_name: Error attempting to access
the WBEM server;
CIM_ERR_NOT_FOUND:
The requested
object could not be found: Instance not
found for RpID: rpid and datetime:
2006...,GUID: n.
For systems running HP-UX 11.11,
apply patch PHSS_34428; for systems
running HP-UX 11.23, apply patch
PHSS_34429.
The system specified by
system_name during data
collection is running Version
2.00.09 of HP-UX WBEM Services
without required patches.
system_name: Error creating object.
Command warning messages
Within the messages sections, messages appear in alphabetical order. Messages that start with
system_name are placed at “s” in a list.
These messages alert you to specific conditions present in the user interface or data collection.
Follow-up actions may or may not be necessary.
For additional information, refer to
“Command reference” (page 129)
in this guide, as well as the
HP SIM Technical Reference Manual or the HP SIM User Guide.
170
Capacity Advisor messages