WARNING:

If the water in the supply line or water solenoid

valve freezes, the S.A.F.E. system will be

INOPERATIVE!!

The manual ball cock shutoff valve must be located outside

of the dryer at a distance from the dryer where it is easily

accessible.

Electrical Requirements

No independent external power source or supply connection

is necessary. The 24 volt power to operate the S.A.F.E. system

is accomplished internally in the dryer (from the dryer

controls).

WARNING:

Electrical power must be provided to the dryer

at ALL times. If the main electrical power supply

to the dryer is disconnected, the S.A.F.E.

system is INOPERATIVE!!

S.A.F.E. SYSTEM THEORY OF OPERATION

While the dryer is in an idle state, or 20-seconds after the

heat turns off, the Phase 7 control monitors the thermistor

probe, located in the top of the basket (tumbler) chamber,

and records the minimum temperature. If the minimum

recorded thermistor probe temperature is greater than 120°

F (48° C) and the control detects a 50° rise in temperature,

this will be the trip point and the S.A.F.E. system routine will

activate.

While a drying cycle is in process and the heat has turned on

at least once, the Phase 7 control monitors the exhaust

temperature transducer. If the drying cycle temperature set

point is set greater than 160° F (71° C) and the control detects

an exhaust temperature rise 25° F greater than set point, this

will be the trip point and the S.A.F.E. system routine will

activate. If set point is below 160° F (71° C), the trip point will

be 185° F (85° C).

Once the S.A.F.E. system routine is activated, the control will

display “S.A.F.E. SYSTEM ACTIVATED” and water will be

injected into the basket (tumbler) chamber. Any time water is

being injected into the basket (tumbler), the basket (tumbler)

drive will turn the load for 1-second every 15-seconds. This

process will continue for a minimum of 2 minutes. After the 2

minutes have elapsed, the control will check if the temperature

remained above trip point; if so, the water will remain on. The

control will continue to check if the temperature is above trip

point every 30-seconds. If the water has been on for a constant

10 minutes, the water will be turned off, regardless of the

temperature, and the control will display “S.A.F.E. SYSTEM

WAS ACTIVATED.” If the temperature has dropped below trip

point, the control will turn off the water prior to 10 minutes.

SYSTEM RESET

After the microprocessor determines that the situation is under

control and shuts the water being injected into the basket

(tumbler) off, the microprocessor display will read “S.A.F.E.

SYSTEM WAS ACTIVATED,” and the horn/tone will sound until

reset manually.

NON-COIN – To reset the microprocessor once the control

displays “S.A.F.E. SYSTEM WAS ACTIVATED,” press the red

“STOP/CLEAR” key on the keyboard (touch pad).

COIN – To reset the microprocessor once the control displays

“S.A.F.E. SYSTEM WAS ACTIVATED,” press and hold the red

“PAUSE” key for 3-seconds on the keyboard (touch pad).

S.A.F.E. SYSTEM WATER VALVE CHECK

The operation of the water solenoid valve can be tested to

ensure that the water supply system and valve are functional.

Before attempting a system check, be sure that ALL water

supply shutoff valves to the dryer are in the OPEN position;

the dryer must be in the “READY” mode with no cycle loaded

or in progress.

NON-COIN

•

Press and hold the red “STOP/CLEAR” key (while

in “READY” mode and no cycle is in progress).

•

Press and hold the “A” key.

•

Water valve will open and water will be dispensed

into basket (tumbler) area as long as both keys

are held.

The Phase 7 non-coin microprocessor controller (computer)

will prompt the user to perform a S.A.F.E. system valve check

at every 4000 hours to ensure proper functionality. At the

4000 hour mark, the control will wait for end of the cycle and

then will prompt the user to “PLEASE EMPTY TUMBLER,

THEN

PRESS

THE

‘STOP/CLEAR’ AND ‘A’ KEYS TO TEST THE WATER VALVE.”

When the ‘STOP/CLEAR’ and ‘A’ keys are pressed, the control

will activate the S.A.F.E. system water valve for 2-seconds, at

which point the control will prompt the user with the following

message: “IF WATER DID NOT TURN ON, CALL FOR

SERVICE. THANK YOU.”

NOTE:

The control will not let the user continue until

the valve test has been completed.

COIN

While the control is in the program mode, Press and hold the

PAUSE key for 3-seconds to get into the valve test mode.

Valve test mode: The control will display “PRESS AND HOLD

MEDIUM TO OPEN WATER VALVE”. When the medium key is

pressed, the control will activate the water output

S.A.F.E. SYSTEM DIAGNOSTICS

NON-COIN – In the event that the Phase 7 non-coin

microprocessor controller (computer) detects a fault in the

S.A.F.E. system, the control will display the message “S.A.F.E.

SYSTEM DISABLED…READY.” To find out why the S.A.F.E.

system is disabling, press and hold the red “STOP/CLEAR”

and green “START” keys. This will cause the control to display

a diagnostic message, as detailed in the “S.A.F.E. SYSTEM

Diagnostics Messages” section.

COIN – In the event that the Phase 7 non-coin microprocessor

controller (computer) detects a fault in the S.A.F.E. system,

the control will display the message “S.A.F.E. SYSTEM

DISABLED…READY, INSERT XX TO START.” To find out the

reason for the S.A.F.E. system disabling, press and hold the

red “PAUSE” and “LOW” keys. This will cause the control to

display a diagnostic message, as detailed in the following

section.

!

!

!