For added personal safety, when possible, it is suggested

that a separate ground wire (no. 18 minimum) be connected

from the ground connection of the dryer to a grounded cold

water pipe. DO NOT ground to a gas pipe or hot water pipe.

The grounded cold water pipe must have metal-to-metal

connection ALL the way to the electrical ground. If there are

any nonmetallic interruptions, such as, a meter, pump, plastic,

rubber, or other insulating connectors, they must be jumped

out with no. 4 copper wire and securely clamped to bare

metal at both ends.

IMPORTANT:

For personal safety and proper operation, the

dryer must be grounded.

Provisions are made for ground connection in each dryer at

the electrical service connection area.

Electrical Connections

A wiring diagram is located inside the control box for

connection data.

If local codes permit, power to the dryer can be made by the

use of a flexible U.L. listed power cord/pigtail (wire size must

conform to rating of dryer), or the dryer can be hard wired

directly to the service breaker panel. In both cases, a strain

relief must be installed where the wiring enters the dryer.

Gas and Steam Models Only

IMPORTANT:

A separate protected circuit must be provided

to each dryer.

Single-Phase (1ø) Wiring Connections/Hookup

The electrical input connections on ALL single-phase

(1ø) gas dryers and steam dryers are made into the rear

service box located at the upper left area of the dryer.

6LQJOH3KDVH (OHFWULFDO /HDG &RQQHFWLRQV

%ODFN

3RVLWLYH

:KLWH RU 5HG

1HXWUDO

RU /

*UHHQ

*URXQG

For 110V Applications

!

!